              V3 PRODUCT LIST

               

              Serial Number

              Name

              Type

              Brief Introduction

              1

              Application software

              AMRS2020

              Application software installed on user’s computer. It is designed for V3 advanced centralized measurement system. By it you can complete the configuration of a new concentrator, you can read all data from V3 meters, and operate the all action of the meters. By its database the software can manage the meters, HUBs, and concentrators, so it is a efficient tool in new project debug.

              2

              Concentrator

              JDG29

              3P4W power supply. By LORA channel auto read active and reactive energy data from meter, and store them in itself. Support interactive action between application software and meters. Support event report which auto from meter. Dimension: 290mm × 178mm × 98mm.

              3

              Concentrator

              JDG27

              3P3W power supply. By LORA channel auto read active and reactive energy data from meter, and store them in itself. Support interactive action between application software and meters. Support event report which auto from meter. Dimension: 290mm × 178mm × 98mm.

              4

              Concentrator

              JDG32

              Next version. Auto adapt to the connection of power supply. By LORA channel auto read active and reactive energy data from meter, and store them in itself. Support interactive action between application software and meters. Support event report which auto from meter. Support AES-128bit message encryption. Up to 15 levels of auto communication relay. Dimension: 290mm × 178mm × 98mm.

              5

              3P4W energy meter

              DTSFI03ABM

               Indirect energy meter, 2.5(10) A, class index 0.5S.  Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply LORA channel with external antenna. Support AES-128bit message encryption. Possess open box detection. Support rail installation. Supply measurement data to user display. Dimension: 185mm × 97mm ×104mm.

              6

              3P4W energy meter

              DTSW(X)01AHN

               Direct energy meter, 5(100) A, class index 1.  Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply BBS channel with built-in antenna. Support AES-128bit message encryption. Support rail installation. Supply measurement data to remote display. Dimension: 185mm × 97mm ×104mm.

              7

              3P3W energy meter

              DSSW(X)01AHN

               Direct energy meter, 5(100) A, class index 1.  Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply BBS channel with built-in antenna. Support AES-128bit message encryption. Support rail installation. Supply measurement data to remote display. Dimension: 185mm × 97mm ×104mm.

              8

              2P3W energy meter

              DSSW(X)02AHN

               Direct energy meter, 5(100) A, class index 1.  Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply BBS channel with built-in antenna. Support AES-128bit message encryption. Support rail installation. Supply measurement data to remote display. Dimension: 185mm × 97mm ×104mm.

              9

              1P2W energy meter

              DDSW(X)01AHN

               Direct energy meter, 5(100) A, class index 1.  Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply BBS channel with built-in antenna. Support AES-128bit message encryption. Support rail installation. Supply measurement data to remote display. Dimension: 185mm × 64mm ×97mm.

              10

              1P3W energy meter

              DDSW(X)02AHN

               Direct energy meter, 5(100) A, class index 1.  Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply BBS channel with built-in antenna. Support AES-128bit message encryption. Support rail installation. Supply measurement data to remote display. Dimension: 185mm × 64mm ×97mm.

              11

              1P2W energy meter

              DDSY02AGP

               Direct energy meter, 5(100) A, class index 1.  Support prepayment mode. Possess a large number of types of measurement data. Display item conform to OBIS code. Possess Mass power profiles and event records. Support event auto report (last gasp). Apply LORA channel with external antenna. Support AES-128bit message encryption. Support rail installation. Pair with a dedicated display "VDBD02AAN", support STS standard token interaction. Dimension: 185mm × 64mm ×97mm.

              12

              HUB (data collector)

              CDAC02A

              It is as a communication bridge between BBS channel meter and concentrator, manages the communication frame interaction of concentrator, BBS meter, and display. In the communication it realized the exchange of LORA text and BBS text. It auto detect BBS meter in same box, needn't configured. Also it possesses the detection of open meter box. Support

              rail installation. Dimension: 185mm × 64mm ×97mm.

              13

              Display of shared version

              VDAB03AAN

              Installed in user home or public position such as corridors, display the measurement data from energy meter. By itself keyboard it can link with different energy meter in different time, so it can be shared for many user when installed public place. When the energy increases every 0.99 kWh, the meter which link with it will auto renew its display data. In addition to energy, it also display many measurement data such as voltage, current, demand, etc..  Its display code conforms to OBIS. Dimension160mm×120mm×47mm.

              14

              Display of STS version

              VDBD02AAN

              It is dedicated for STS prepayment energy meter of type DDSY02AGP.The difference between it and the displays of shared version is that it can only link one configured STS energy meter to display the measurement data. In addition to, by its keyboard can input STS tokens, then it transmit the token to the energy meter. It can also warning by voice or light when the energy consumption reach up to the threshold. Dimension: 160mm×120mm×47mm.

              15

              Converter between LORA and PLC in communication

              LCG15A

              It is designed for the compatibility of V3 energy meter and old version PLC meter work in same system. It convert received LORA frame to PLC frame for PLC meters, and then convert the responding PLC frame to LORA frame for V3 system. So that by this device, the old version PLC energy meter can work in V3 system. Dimension: 160mm×125mm×63mm. 

              16

              V3 modem of RS232 version

              LDAG19A

              It functions to modulate/demodulate the communication signal. It integrates LORA channel and BBS channel together, connect HHU or computer by RS232 interface. By dedicated software in HHU or computer, you can read or operate the V3 energy meter whether which with channel LORA or BBS. As a tool it supports AES-128bit message encryption. Dimension: 95mm×52mm×32mm.

              17

              V3 modem of BT version

              LDAG20A

              It functions to modulate/demodulate the communication signal. It integrates LORA channel and BBS channel together, by Bluetooth link the cell phone which installed Android system. By dedicated software in cell phone, you can read or operate the V3 energy meter whether which with channel LORA or BBS. As a tool it supports AES-128bit message encryption. Dimension: 95mm×52mm×32mm.

              18

              LORA signal tester

              LAAK14A

              It is used for a new V3 project to evaluate the signal level of LORA in communication. Before devices installation, by this work you can budget the level of communication chain, thereby decide the positions of meters or concentrator to be installed. It can be as a signal source sending LORA frame in dedicated format. Also it can be as a receiver testing the frame signal strength, signal/noise ratio, frame error rate, etc.. So that you at least need 2 testers for the budget work in a new engineering. Dimension: 160mm×120mm×47mm.

               

                

               

              ↑上一篇:←第一篇   ↓下一篇:最后一篇→

              友情鏈接:
              電話:0755-29981535    傳真: 0755-29981536    E-mail:zyj@cstmeter.com   歡迎來電咨詢代理、經銷事宜!
              版權所有©深圳市肯斯特電子有限公司   備案號:粵ICP備19111865號
              久久久久久免色精品|午夜国产精品水蜜桃视频|久久综合给合久久狠狠狠97色69|亚洲精品无码9久久久
              <u id="z8blt"></u>
              <tbody id="z8blt"></tbody>
            1. <menuitem id="z8blt"></menuitem>

                <samp id="z8blt"></samp>
                  <menuitem id="z8blt"></menuitem>
                1. <tbody id="z8blt"></tbody>
                        <tbody id="z8blt"></tbody>

                        <samp id="z8blt"></samp>